Guidance library · 47 questions

Medicines fridges and room storage, answered from the source

Domestic or pharmaceutical fridge, where to put it, how full to fill it, and what the guidance says about rooms and cupboards that run warm.

Reviewed by Jake Farrow, Managing DirectorLast reviewed 19 October 2026

Most temperature problems are cheaper to prevent than to assess. Prevention starts with the right fridge, sited and loaded so air can move, and rooms kept within the range on the pack. The one thing to remember: the product label sets the range, and you need to show your fridge and your room actually hold it.

Why it matters

Why the box and the room matter

A fridge that cannot hold an even temperature produces excursions. SPS explains that medicines fridges use fan cooling and have no ice box or salad drawer, and the NHS Pharmaceutical QA Committee warns that parts of a domestic fridge can routinely drop below freezing (SPS). Freezing can irreversibly damage vaccines and biologicals.

Rooms are easier to forget. CQC expects care home policies to say how staff monitor the temperature of medicines storage areas, including residents' rooms (CQC), and the VMD says its inspectors now expect ambient records wherever medicines are kept (VMD blog).

What the rules say

Pharmaceutical fridge or domestic?

For vaccines the position is clear. The Green Book says vaccines must be stored in specialised pharmaceutical fridges and domestic fridges must not be used, and CQC's GP mythbuster 17 repeats it. For wholesalers, the MHRA Inspectorate blog says a pharmaceutical refrigerator is required.

For other medicines, SPS says domestic fridges are "not recommended" in healthcare settings, and laboratory fridges are unsuitable too. CQC's care home fridge guidance agrees, with one narrow exception: a small service that rarely holds fridge items could use a locked container in the food fridge, with full monitoring and a risk assessment. In supported living, CQC expects medicines to stay in people's own homes (CQC).

Domestic fridges: who says what
ControlGreen BookMHRA blogNHS SPSCQC care homesWHO
Expects a pharmaceutical or dedicated medicines fridge✓✓✓✓✓
Rules a domestic fridge out✓✓···
Allows a narrow exception···✓✓
Warns a 'medical' label is no guarantee·✓·✓·

A filled cell means the source says it. The Green Book covers vaccines, the MHRA blog wholesale storage, and WHO accepts household-style units only if independently tested against a pharmaceutical refrigerator standard.

What a medicines fridge should be

The NHS Pharmaceutical QA Committee's model specification makes a good buying checklist: cleanable materials, no freezer box, salad drawer or door shelves, automatic defrost, grille shelving, an internal fan and a lock. The MHRA blog adds a calibrated min/max thermometer accurate to ±0.5 °C, readable without opening the door, and checking how the unit copes with power cuts and hot spells.

For freezers, the MHRA's freezer blog says fridge ice boxes are "not supported in any circumstance" for GDP use and warns that domestic auto-defrost cycles can cause high excursions.

What good looks like

Placing and loading the fridge

SPS recommends a 5 °C set point, clearance on all sides away from heat, feet levelled so the door swings shut, and protection against switch-off (see Power failures and contingency). The Green Book adds a ventilated site, a unique identifier and at least yearly servicing, with servicing, defrosting, cleaning, calibration and PAT testing logged beside the fridge.

Loading is about air. SPS says not to overfill, to keep stock off the walls and base, and to use mesh baskets rather than solid trays. The Green Book warns that vaccines against the back wall may freeze, and UKHSA's poster says to keep them in original packaging, shortest-dated at the front. No food, drink or specimens, and the RPS says lock the fridge when not in use.

The MHRA blog puts the probe centrally, not in the door; EU GDP and WHO put it where mapping shows the extremes; SPS suggests an air sensor plus a load sensor. See Mapping and qualification and Monitoring, alarms and calibration.

Rooms, cupboards and the 25 °C question

SPS says that ideally all medicines storage areas would be held between 15 °C and 25 °C, with air conditioning where possible and ambient cabinets for small quantities where not (SPS). UKHSA's hot weather guidance says "most medicines should be kept below 25°C". Neither replaces the pack: ambient ranges run from 8 °C to 30 °C, and storing outside them takes a medicine outside its licence.

Watch the bottom of the range too: the VMD recommends avoiding ambient storage below 12 °C because of condensation. Products with no storage statement still need monitoring, says the EMA GDP Q&A.

SPS treats a min/max recorder as the minimum in storage locations, and the 2015 QA Committee document asks for daily readings in the worst-case spot. That was written for NHS wards; care homes and GP practices usually adopt it by analogy.

In a heatwave

If a room goes over, it is an excursion. SPS says a single, isolated excursion of less than 5 °C above the labelled maximum, lasting under seven days, is unlikely to harm medicines. It does not cover rooms that run hot every summer, or relax wholesale requirements. The assessment is on Temperature excursions. SPS's hot weather measures:

  • Keep stock to a minimum, with strict rotation.
  • Move medicines out of direct sun; consider reflective window film.
  • Keep windows and doors shut unless it is cooler outside.
  • Do not move ambient medicines into the fridge unless the label allows it.
  • Remind patients not to leave inhalers in parked cars (SPS on heatwaves).

Worked example

An illustrative July afternoon

This is an illustrative example in a care home. Wednesday 15:00 in a July heatwave, the medicines room min/max reads 26.8 °C now, 27.5 °C maximum; yesterday's maximum was 26.9 °C. Most stock is labelled "do not store above 25 °C".

The senior carer records both readings and escalates to the supplying pharmacist. One event, under 5 °C over, two days so far: inside SPS's single-excursion rule. They draw the blinds, move the trolley off the sunny wall and confirm the fridge has stayed below 8 °C. The decision and the pharmacist's name go on the record.

In September the manager notes the room has passed 25 °C two summers running, so it is no longer isolated, and the risk assessment now plans an ambient cabinet or cooling.

Where it is unclear

Where the sources disagree

Domestic fridges get three answers: never for vaccines, not recommended otherwise, and acceptable to WHO only if independently tested (domestic fridges). Probe placement depends on whether you follow the MHRA default or your mapping (centre or extremes?).

For rooms, UKHSA's 25 °C rule, SPS's single-excursion tolerance and the 2015 QA Committee's stricter trigger (more than 5 °C over, or more than a day) sit side by side (25 °C ceiling or a tolerance?). For rooms that spike every afternoon, SPS describes mean kinetic temperature, which the MHRA Inspectorate discourages in wholesale (MKT).

Inspection findings

What inspectors have found

The MHRA's 2016 GDP deficiency data cited a walk-in fridge with dirt around the fans and no cleaning schedule. Its 2016 GMP data includes a fridge checked only weekly with no max/min readout and a receiving area not monitored against its limit. VMD inspectors can seize products whose storage may have compromised them.

In summary

The short version

  • Use a pharmaceutical or dedicated medicines fridge, and never a domestic fridge for vaccines.
  • Check the unit holds +2 °C to +8 °C in your room, at your load.
  • Site it with clearance, away from heat, levelled and protected from switch-off.
  • Load for airflow: off the walls and base, original packaging, nothing but medicines.
  • Log servicing, cleaning, defrosting, calibration and PAT testing beside the fridge.
  • Monitor rooms as well as fridges, against each product's label.
  • Plan for hot weather, and fix a room that runs hot every summer.

Fridges and room storage

Questions, answered from the source

Last checked 19 October 2026. Each answer links to its source and says whether it is law, formal guidance or interpretation.

What storage temperatures does UK law set for red cells, platelets and granulocytes?Law

Part 4 of the Schedule to the Blood Safety and Quality Regulations 2005 sets liquid storage at +2 to +6°C for red cell preparations and whole blood (28 to 49 days depending on process), +20 to +24°C for platelets (5 days, or 7 with bacterial detection or reduction) and +20 to +24°C for granulocytes (24 hours). It also says transport and distribution at every stage of the transfusion chain must maintain product integrity. Regulation 7 requires blood establishments to comply with Part 4.

What's agreed, and what isn't

The Regulations give cryopreservation durations (for example plasma and cryoprecipitate up to 36 months) but no frozen storage temperature; the -25°C figure for FFP comes from the JPAC Red Book. Transport has no numeric range in law, only the integrity requirement.

Status
Law
Applies to
Blood
Last checked
18 October 2026
Can we keep staff milk or specimens in the medicines fridge, and does it need a lock?Guidance

No. RPS says fridges and freezers used for medicines must not store other items, should be locked when not in use, and must be protected from accidental switch-off. They should not be overloaded, and medicines should not touch the sides or base, so that air can circulate. SPS, the NHS Pharmaceutical QA Committee and the SW ICARS toolkit all say the same about food and specimens.

What's agreed, and what isn't

Locking can be met by a lockable fridge or a locked room, as the SW ICARS toolkit notes for vaccine fridges.

Status
Formal guidance
Applies to
All settings
Last checked
18 October 2026
Can we use a domestic fridge to store medicines in a care home or GP practice?Guidance

SPS says domestic fridges and freezers are not recommended for storing medicines in healthcare settings, and that cold chain medicines should be kept in a specialist medicines fridge or freezer. Medicines fridges use fan cooling and have no ice box or salad drawer, so the temperature is more even. SPS also says not to use a laboratory fridge. The NHS Pharmaceutical QA Committee warns that parts of a domestic fridge can routinely drop below freezing.

What's agreed, and what isn't

The SPS article does not mention care homes, and "not recommended" is guidance, not a legal ban. In care homes, a resident's few fridge items have sometimes been kept in a lockable domestic-style fridge. SPS gives no exemption for this, and local ICB or CQC expectations should be checked. The NHS England SW ICARS toolkit is firmer for vaccines: "Do not use a domestic fridge."

Status
Formal guidance
Applies to
Care homes, GP practices, Hospitals and wards, Dental, Community pharmacy
Last checked
18 October 2026
Do we need to temperature map a pharmaceutical fridge, and can a household fridge be used?Guidance

WHO model guidance says refrigerators and freezers should be purpose-designed, and household-style units are acceptable only if independently tested against a recognised standard for pharmaceutical refrigerators. It says qualification may not be needed for equipment with little or no site assembly that has been independently tested, provided it is installed correctly. WHO's mapping supplement explicitly does not cover refrigerators or freezers, because they are generally tested and prequalified independently.

What's agreed, and what isn't

WHO's later Good Storage and Distribution Practices guideline (TRS 1025, Annex 7, 2020) lists refrigerators and freezers among the places where mapping should be done, which conflicts with Supplement 8. Follow your inspector's or sector guidance, and document why you did or did not map.

Status
Formal guidance
Applies to
Wholesalers (WDA), Hospitals and wards, Laboratories, Community pharmacy
Last checked
18 October 2026
Does in-use insulin for a self-administering patient on the ward need to stay in the fridge?Guidance

SPS's self-administration guidance says in-use insulin does not require refrigeration. It can be kept with the patient's other medicines, or outside secure storage after a local risk assessment. Some medicines, such as reliever inhalers, GTN spray and insulin, may be exempt from locked storage, subject to risk assessment.

What's agreed, and what isn't

Unopened insulin stock still needs 2-8 °C. In-use storage limits, such as days at room temperature and maximum temperature, are product-specific in the SmPC.

Status
Formal guidance
Applies to
Hospitals and wards
Last checked
18 October 2026
During a heatwave, what should we tell patients or care staff about storing insulin, inhalers and auto-injectors?Guidance

SPS repeats MHRA advice to store medicines somewhere cool, dry and out of direct sunlight. Insulin should be kept in a fridge or a cool bag, and replaced if blood glucose is unexpectedly high in case heat has damaged it. Inhalers should not be left in parked cars, because heat can damage them or make pressurised inhalers burst. Adrenaline auto-injectors should be checked for damage or discolouration. In anaphylaxis, use of an auto-injector should not be delayed because of possible heat exposure if no alternative is to hand.

What's agreed, and what isn't

This page covers patient risk rather than stock storage. It does not give stockroom or care home room-temperature limits.

Status
Formal guidance
Applies to
Care homes, Community pharmacy, GP practices
Last checked
18 October 2026
How must retention and reference samples be stored, and for how long?Guidance

The revised Annex 19 (applicable from 24 September 2026) says reference and retention samples of each finished product batch should be kept for at least one year after the expiry date (3.1), stored in line with the guidance on declaration of storage conditions (5.1) and the marketing authorisation, for example refrigerated where relevant (5.2).

What's agreed, and what isn't

MHRA's 2015 GMP deficiency examples include a retention sample store with no temperature logger nearby, and a site with no storage facilities, monitoring devices or procedures for its reference and retention samples. The sample store is often the least watched room on site.

Status
Formal guidance
Applies to
Manufacturers, Laboratories
Last checked
19 October 2026
How often should a medicines fridge be serviced, and what routine cleaning is expected?Guidance

SPS says a refrigeration specialist should service and calibrate fridges annually, and that portable appliance testing should follow local policy. Routine care includes wiping door seals and checking them for damage, clearing the drain hole, and dusting accessible condenser coils. Freezers should be defrosted when ice builds up. Cleaning frequency is set locally.

What's agreed, and what isn't

SPS also recommends end-of-shift checklists to confirm the fridge is switched on and in range, but does not say which role does them. The NHS England SW ICARS toolkit asks GP practices to keep the maintenance log with the vaccine fridge.

Status
Formal guidance
Applies to
All settings
Last checked
18 October 2026
How should a medicines fridge be set up and loaded?Guidance

SPS recommends running fridges at 2-8 °C, with 5 °C as a typical mid-point set point. Leave clearance on all sides away from heat sources, and level the feet so the door swings shut if left ajar. Protect the unit from being switched off by accident, for example with a socket guard or fixed spur. Do not overfill it, because pharmacy fridges rely on chilled air moving around the chamber. Keep stock off the walls and base, and use mesh baskets rather than solid trays or polystyrene.

What's agreed, and what isn't

SPS accepts brief excursions during stock handling if the temperature recovers quickly. Anything else goes through the excursion process.

Status
Formal guidance
Applies to
All settings
Last checked
18 October 2026
How should platelets be stored, and what happens if the agitator stops?Guidance

Platelets are stored at a core temperature of 22 ±2°C with continuous gentle agitation, for up to 5 days in a closed system (7 days only with bacterial screening or pathogen inactivation). If agitation is interrupted, for example by equipment failure or long transport, the platelets keep the same shelf life as long as no single interruption lasts more than 8 hours and all interruptions total no more than 24 hours. Transport containers should be equilibrated at room temperature, and on receipt the platelets go back to 22 ±2°C storage with agitation.

What's agreed, and what isn't

Platelets need controlled room-temperature storage, not a fridge. Monitoring of the incubator or agitator, and of room temperature where open shelving is used, is implied but not specified.

Status
Formal guidance
Applies to
Blood, Hospitals and wards
Last checked
18 October 2026
Is there official hot-weather guidance saying medicines must be kept below 25 °C?Guidance

UKHSA's hot weather guidance for healthcare professionals says "Most medicines should be kept below 25°C", somewhere cool and dry, away from direct sunlight and windowsills. It also says medicines should only go in the fridge if their labelling specifies it, and refers readers to SPS for more detail on medicines storage.

What's agreed, and what isn't

The NHS England Heatwave Plan has been replaced by UKHSA's Adverse Weather and Health Plan. The 25 °C figure is a general rule: the pack or SmPC decides, and some products allow 30 °C. Putting ambient medicines in the fridge to cool them is discouraged unless the labelling allows it. SPS permits creams, ointments and suppositories only after checking with a pharmacist.

Status
Formal guidance
Applies to
Care homes, GP practices, Hospitals and wards, Community pharmacy
Last checked
18 October 2026
We make an API. What does GMP Part II say about storage temperature?Guidance

Part II (ICH Q7) says materials should be stored under conditions and for a period that do not adversely affect their quality (7.42). Storage facilities should hold materials under appropriate conditions, for example controlled temperature and humidity when necessary, and records should be kept of those conditions "if they are critical for the maintenance of material characteristics" (10.10). Utilities that could affect quality, such as HVAC, should be qualified and monitored, with action when limits are exceeded (4.20).

What's agreed, and what isn't

Special transport or storage conditions should be on the label (10.22), and carriers must know and follow them (10.23). MHRA's 2016 deficiency examples include an API shipped without temperature monitoring despite needing storage at 25 °C or below.

Status
Formal guidance
Applies to
Manufacturers
Last checked
19 October 2026
What does EU GMP actually say about temperature in a manufacturer's warehouse and stores?Guidance

Chapter 3, paragraph 3.19 says storage areas should be clean and dry and maintained within acceptable temperature limits, and where special storage conditions are required (for example temperature or humidity) they "should be provided, checked and monitored". Chapter 5 adds that all materials and products should be stored under the conditions established by the manufacturer (5.7), including intermediates and bulk (5.41), quarantined finished product (5.63) and released stock (5.65).

What's agreed, and what isn't

Chapter 3 never uses the words "mapping" or "alarm". MHRA inspectors have linked 3.19 to mapping in replies on their blog (a mapping study to define where probes go), and paragraph 3.3 extends the same expectation to conditions that could affect equipment. Quarantine, rejected and returned stock need their own marked, segregated areas (3.21, 3.23).

Status
Formal guidance
Applies to
Manufacturers
Last checked
19 October 2026
What does GMP expect for QC lab fridges and freezers holding samples, reagents and reference standards?Guidance

Chapter 6 says samples should be protected from adverse storage conditions (6.13), sampling procedures must state storage conditions (6.11), reagents and culture media should be labelled with their storage conditions (6.21) and storage instructions followed (6.22). Chapter 3 asks for adequate storage space for samples and records (3.27).

What's agreed, and what isn't

MHRA deficiency examples show where labs fall short: room temperature not recorded in sample and standard storage areas (2015), and a standards fridge checked only weekly with no max/min readout (2016). Treat a lab fridge holding reference standards like any other GMP storage unit.

Status
Formal guidance
Applies to
Manufacturers, Laboratories
Last checked
19 October 2026
What room temperature should medicines storage areas be kept at, and what can we do in hot weather without air conditioning?Guidance

SPS says that ideally all medicines storage areas would be controlled between 15 °C and 25 °C, which suits all ambient medicines. Air conditioning should be installed if possible. If it cannot be, ambient storage cabinets held at 15-25 °C can be used for small quantities. In hot weather, SPS advises keeping stock to a minimum with strict rotation, moving medicines out of direct sun, using reflective window film, and keeping windows and doors closed unless it is cooler outside. Check SmPCs, since some allow higher storage temperatures.

What's agreed, and what isn't

Manufacturers' ambient ranges can be anywhere from 8 °C to 30 °C, and the pack always takes precedence. SPS says storing a medicine outside its stated conditions takes it outside its licence and needs review under local clinical governance. The page does not set how often room temperature should be checked.

Source
Storing medicines at ambient temperatures NHS SPS, 24 June 2026
Status
Formal guidance
Applies to
Hospitals and wards, GP practices, Care homes, Community pharmacy
Last checked
18 October 2026
What specification should a ward medicines fridge meet?Guidance

The NHS Pharmaceutical QA Committee's model specification is: impervious, cleanable materials; a single cooler panel with no freezer box, salad drawer or door shelves; holds 2-8 °C; automatic defrost; grille shelving; an internal air-circulating fan; and a lock or child-resistant closure. Optional features are an external temperature display, an out-of-range alarm and a door-open alarm. It says cold chain medicines should always be stored in pharmacy-specification fridges.

What's agreed, and what isn't

The current SPS article makes the same broad point, adds that a laboratory fridge is unsuitable, and calls continuous monitoring and alarms good practice rather than optional extras.

Status
Formal guidance
Applies to
Hospitals and wards, Care homes, GP practices
Last checked
18 October 2026
What temperature and humidity does a stability chamber have to hold?Guidance

ICH Q1A(R2) sets the standard conditions. General case: long term 25 °C ± 2 °C/60% RH ± 5% RH or 30 °C ± 2 °C/65% RH ± 5% RH, intermediate 30 °C ± 2 °C/65% RH ± 5% RH, and accelerated 40 °C ± 2 °C/75% RH ± 5% RH. Refrigerated products: long term 5 °C ± 3 °C, accelerated 25 °C ± 2 °C/60% RH ± 5% RH. Frozen: long term −20 °C ± 5 °C. Products stored below −20 °C are treated case by case.

What's agreed, and what isn't

Semi-permeable containers have their own lower-humidity conditions. The tolerances are what the chamber must hold, so your monitoring limits sit inside them. A consolidated ICH Q1 revision was published as a Step 2 draft in April 2025 and was not final when this was checked.

Status
Formal guidance
Applies to
Manufacturers, Laboratories
Last checked
19 October 2026
What temperature should fresh frozen plasma be stored at, and how long is it good after thawing?Guidance

FFP should be stored at a core temperature of -25°C or below for up to 36 months; colder storage preserves coagulation factors better but makes packs more fragile. Thaw in purpose-designed equipment at 33-37°C (37°C optimal) and never refreeze. Thawed FFP should be used within 4 hours at 22 ±2°C, or up to 120 hours at 4 ±2°C, depending on indication. Pre-thawed FFP may go back into 4 ±2°C storage only once and only if it was out for under 30 minutes.

What's agreed, and what isn't

For indications other than unexpected major haemorrhage the Red Book says to use FFP within 24 hours of thawing, so the 120-hour limit does not apply to every use. The BSQR give no frozen temperature; -25°C comes from the Red Book.

Status
Formal guidance
Applies to
Blood, Hospitals and wards
Last checked
18 October 2026
What temperature should mortuary fridges and freezers run at under the HTA?Guidance

HTA post-mortem standard PFE2 guidance says bodies should be refrigerated at approximately 4°C, and the optimal operating temperature for freezer storage is around -20°C. Bodies should be moved to frozen storage after 30 days in refrigerated storage if they are not soon to be released or examined, or sooner depending on their condition. Bodies in long-term storage should be checked regularly.

What's agreed, and what isn't

These are approximate targets, not a tolerance band. Each establishment sets its own acceptable range and alarm trigger points, which must be documented and known to staff.

Status
Formal guidance
Applies to
Tissue and mortuary
Last checked
18 October 2026
Can a care home use a domestic fridge, or a box in the food fridge, for residents' refrigerated medicines?Interpretation

CQC says dedicated medicines fridges should be used and domestic fridges are 'not recommended as they do not guarantee a stable temperature'. It also warns that some fridges advertised as 'medicines fridges' may hold temperatures that are too low or too high, so check the fridge can actually maintain 2-8°C. As an exception, small services that do not regularly keep refrigerated medicines could use a separate locked container in the food fridge, accessible only to trained staff, with full temperature monitoring and a full risk assessment.

What's agreed, and what isn't

This is softer than the Green Book and CQC's GP mythbuster, which say vaccines must never go in a domestic fridge. The locked-box allowance is for 'exceptional circumstances' in small services, not routine practice. Vaccines held by nursing homes should follow the stricter Green Book standard.

Status
Interpretation
Applies to
Care homes
Last checked
18 October 2026
More on
Care homes
Can a dental practice keep its GlucaGen HypoKit in the emergency kit instead of the fridge?Interpretation

Yes. CQC dental mythbuster 4 says GlucaGen HypoKit should be stored at 2-8°C and not frozen, but it can be kept outside the fridge at no more than 25°C for 18 months, provided the manufacturer's expiry date is not exceeded, in its original package to protect it from light. The practice must be able to show either when the product came out of the fridge (for example a label with that date or a revised expiry) or that it is still safe, for example a purchase invoice showing that 18 months have not passed since delivery.

What's agreed, and what isn't

The 25°C limit means the room or kit location itself needs to stay below 25°C, and the mythbuster does not say how that should be evidenced. The 18-month figure is product-specific to GlucaGen HypoKit.

Status
Interpretation
Applies to
Dental
Last checked
18 October 2026
Can a GP practice keep glucagon in the emergency drugs box at room temperature?Interpretation

CQC GP mythbuster 1 says glucagon ideally requires refrigeration, but if it is stored at room temperature its expiry date is reduced and the practice should record a new expiry date. Emergency medicines should be readily accessible and not locked away, ideally in a tamper-evident box marked 'for emergency use'. Medicines with extra legal storage requirements, such as safe custody, are the exception.

What's agreed, and what isn't

The GP mythbuster does not give the shortened shelf life. CQC's dental mythbuster 4 states the GlucaGen HypoKit figure (up to 18 months at no more than 25°C, within the original expiry). Other glucagon products may differ, so check the SPC.

Status
Interpretation
Applies to
GP practices
Last checked
18 October 2026
Can a wholesaler use a domestic fridge, or one just labelled 'medical', for fridge lines?Interpretation

The MHRA inspector's blog says a pharmaceutical refrigerator is required for refrigerated medicinal products. It describes these as fan-circulated for a uniform temperature and fast pull-down after door opening, monitored by a calibrated electronic min/max thermometer accurate to ±0.5°C that can be read without opening the door. Quoting the Green Guide, it warns that a fridge 'purported to be medical or pharmaceutical' is not automatically suitable. It should have no internal ice box and no internal dials that can be knocked.

What's agreed, and what isn't

The blog is aimed at wholesale (GDP) storage; other settings such as GP practices and pharmacies follow their own guidance (for example the Green Book and SPS), which is broadly similar. When buying, the blog suggests checking how long the unit holds temperature during a power cut and how it copes with hot spells.

Status
Interpretation
Applies to
Wholesalers (WDA)
Last checked
18 October 2026
Can we use a domestic freezer, or the ice box of a fridge, for frozen medicines or cold packs?Interpretation

The MHRA freezer blog says refrigerator ice boxes are 'not supported in any circumstance' for GDP use. It warns that domestic freezers may have auto-defrost cycles causing high excursions and are less able to hold a narrow range. Freezers storing medicines should be dedicated, or shown not to be affected by freezing cold packs. Most frozen medicines need -15°C to -20°C, and freezers must be qualified, monitored and mapped like refrigerators.

What's agreed, and what isn't

The blog does not ban domestic freezers outright; it lists their drawbacks and leaves the choice to qualification evidence. It also flags that combined fridge-freezers on one compressor can compromise both compartments. If you only stock a few frozen lines, it suggests not holding them or outsourcing.

Source
Use of Freezers MHRA, 20 June 2017
Status
Interpretation
Applies to
Wholesalers (WDA)
Last checked
18 October 2026
Does a supported living or Shared Lives service need its own medicines fridge?Interpretation

No. CQC says medicines should be stored in people's own homes rather than centrally, including medicines that need a fridge, and that supported living services do not need a separate medicines fridge or controlled drugs cupboard. Providers should work with each person to store medicines in a way that meets their needs and the manufacturer's requirements. CQC's Shared Lives page says the same for Shared Lives carers.

What's agreed, and what isn't

CQC does not say how temperature should be assured when refrigerated medicines sit in a person's domestic fridge. Providers usually handle this through the individual risk assessment and care plan.

Source
Managing medicines in supported living CQC, 20 February 2023
Status
Interpretation
Applies to
Care homes
Last checked
18 October 2026
Does CQC require care homes to monitor room temperature where medicines are stored, and what limit applies?Interpretation

Yes. CQC says policies and procedures must set out how staff will monitor the temperature of medicines storage areas, so that medicines are kept as the manufacturer recommends. Providers also need a way for staff to escalate storage concerns or seek advice. CQC suggests a medicines storage risk assessment that, as a minimum, considers the temperature requirements of the medicines, including those kept in residents' own rooms.

What's agreed, and what isn't

CQC's page gives no numeric room-temperature limit and no recording frequency. The commonly used 'below 25°C' comes from product labels and local ICB guidance, not from CQC. Rooms where residents self-administer are within scope, which is hard to monitor in practice; a risk assessment is the expected route.

Source
Storing medicines in care homes CQC, 3 November 2022
Status
Interpretation
Applies to
Care homes
Last checked
18 October 2026
If a medicine has no storage conditions on the label, do we still need to monitor its temperature?Interpretation

Yes. EMA's GDP Q&A says it is not acceptable to leave storage unmonitored. A product without a storage statement has been justified by stability data at 25°C/60% RH or 30°C/65% RH (long term) and 40°C/75% RH (accelerated), reflecting climate zones I and II. Controls should therefore keep conditions relevant to those zones, temperature should be monitored during storage and transport, and appropriate monitoring limits should be set.

What's agreed, and what isn't

The Q&A does not give a specific numerical limit; you have to set and justify one. It applies to EU GDP, which MHRA applies in the UK through its GDP guidance, but check MHRA's own position for UK-specific nuance.

Status
Interpretation
Applies to
Wholesalers (WDA), Transport
Last checked
18 October 2026
Is it a problem if our pharmacy fridge is packed full, or we chill gel packs in it?Interpretation

Quoting the Green Guide, the MHRA blog says enough space should be kept for air circulation, products should not touch the walls or floor, and if a fridge is filled to capacity, the effect on temperature distribution should be investigated. Where non-refrigerated items such as unconditioned gel packs go into the fridge, the temperature rise they cause should be assessed. Stock of different status (incoming, quarantine, returned, outgoing) should be segregated.

What's agreed, and what isn't

No fill limit is given; the expectation is evidence (for example mapping at full load) rather than a percentage rule. The 2017 freezer blog makes the same point for freezers, recommending dedicated units for medicines rather than shared use for conditioning cold packs.

Status
Interpretation
Applies to
Wholesalers (WDA)
Last checked
18 October 2026
What does CQC expect of the vaccine fridge itself in a GP practice?Interpretation

CQC GP mythbuster 17 restates the Green Book: use a validated fridge designed for pharmaceutical products, never a domestic fridge, and use it only for pharmaceuticals (no food or clinical specimens). Keep it locked or in a locked room, guard against accidental switch-off with a switchless socket or a 'Do not unplug/switch off' label, and make sure it is big enough for air to circulate around the packs. Keep it clean and free of ice, follow the manufacturer's servicing schedule, calibrate the temperature gauge and include it in portable appliance testing.

What's agreed, and what isn't

The mythbuster says to 'calibrate the temperature gauge' but gives no frequency or method; local ICB policy or the fridge manufacturer usually fills that gap. Inspectors assess this under the Safe key question (medicines), so a finding sits within the wider medicines-management judgement.

Status
Interpretation
Applies to
GP practices
Last checked
18 October 2026
What does CQC say about stocking, cleaning and protecting a care home medicines fridge?Interpretation

Make sure the fridge is the right size and do not store large amounts of medicines in it, because poor airflow can lead to freezing. Check dates regularly and rotate stock according to your policy. Clean and defrost the fridge regularly and keep dated records of this. Prevent accidental power interruption with a switchless socket, a 'Do not unplug/switch off' label or a purpose-made socket cover. Keep the fridge secure, accessible only to authorised staff, and free of food and biological samples.

Status
Interpretation
Applies to
Care homes
Last checked
18 October 2026
What temperature ranges do VMD inspectors expect for refrigerated and ambient veterinary medicines?Interpretation

VMD says cold chain products must be stored at 2-8°C and most ambient products below 25°C. It also recommends avoiding ambient storage below 12°C, because that is close to the dew point indoors and condensation can damage packaging and labels. Inspectors now expect records showing that ambient storage stays within range, not just cold chain records, in every location where medicines are kept. Medicines and vaccine fridges must not hold staff food, and inspectors can seize products whose storage may have compromised them.

What's agreed, and what isn't

The 12°C lower ambient limit is a VMD inspector recommendation, not a label requirement. RCVS supporting guidance uses an 8-25°C ambient band, so practices may see slightly different figures. The SPC always governs.

Status
Interpretation
Applies to
Veterinary
Last checked
18 October 2026
Where should the temperature probe go in a fridge, and how should we stock it?Interpretation

The MHRA blog says calibrated probes should be placed centrally, preferably between products, and not in the door. Products should be stored in an orderly way on shelves, not on the floor, so air can circulate. The fridge should be cleaned regularly and serviced at least annually, any alarm tested routinely at specified temperatures, stock rotated first expiry first out, and no food or drink kept in it.

What's agreed, and what isn't

This placement advice is a general default. EU GDP and the MHRA mapping blog expect permanent probes to be placed where mapping shows the extremes, which may not be the centre. Where these conflict, follow your mapping data and document why.

Status
Interpretation
Applies to
Wholesalers (WDA)
Last checked
18 October 2026
Can we keep food, drink or specimens in the vaccine fridge?Guidance

No. The Green Book says food, drink and clinical specimens must never be stored in the same fridge as vaccines. The 2014 protocol says the vaccine fridge should be used only for vaccines and medicines.

What's agreed, and what isn't

The protocol allows other medicines alongside vaccines. Northern Ireland is stricter and says the vaccine fridge should not store anything other than vaccines.

Status
Formal guidance
Applies to
GP practices, Community pharmacy, Care homes
Last checked
18 October 2026
Can we store vaccines in a domestic fridge?Guidance

No. The Green Book says vaccines and diluents must be stored in specialised pharmaceutical fridges and ordinary domestic fridges must not be used. The 2014 protocol says all practices should have a validated vaccine fridge, as domestic fridges are not suitable.

What's agreed, and what isn't

This is one of the clearest positions in UK vaccine guidance; Scotland and Northern Ireland say the same. The UKHSA incident checklist asks whether the fridge is domestic or medical, so a domestic fridge will count against you in any incident review.

Status
Formal guidance
Applies to
GP practices, Community pharmacy, Care homes
Last checked
18 October 2026
Do we need a switchless socket or plug guard on the vaccine fridge?Guidance

The Green Book says steps should be taken to reduce the chance of the power being cut off by accident, such as installing a switchless socket or clearly labelling the fridge plug. The 2014 protocol says fridges must be wired into switchless sockets, and the 2026 poster says to mark or tape the plug.

What's agreed, and what isn't

The sources differ on strength: the Green Book accepts labelling as an alternative, while the protocol lists switchless wiring as a 'must'. Public Health Scotland prefers wiring the fridge directly into the supply (a 'spur'), with physical protection of the plug as a fallback. The UKHSA incident checklist asks whether the power supply is protected from disconnection.

Status
Formal guidance
Applies to
GP practices, Community pharmacy
Last checked
18 October 2026
How full can I stock the vaccine fridge, and where should vaccines go?Guidance

The Green Book says to leave enough space around vaccine packages for air to circulate and to keep vaccines away from the side and back walls, where they may freeze. The 2026 poster says not to overfill, to keep vaccines in their original packaging in the main part of the fridge rather than in drawers, and to put the shortest-dated stock at the front.

What's agreed, and what isn't

The Green Book and UKHSA do not give a percentage. Public Health Scotland says no more than two-thirds of the internal volume, with about a 4 cm gap from the walls. Northern Ireland says no more than 50% full and never in the door. Follow the fridge manufacturer's loading guidance where it exists.

Status
Formal guidance
Applies to
GP practices, Community pharmacy
Last checked
18 October 2026
What maintenance records should we keep for a vaccine fridge?Guidance

The Green Book says to keep records of regular servicing, defrosting and cleaning, calibration and electrical (PAT) testing, on a log sheet kept with the fridge. Each fridge should have a unique identifier such as a serial number. It should be serviced at least yearly, sited in a ventilated place away from heat, and kept free of ice build-up.

What's agreed, and what isn't

If the fridge must be defrosted, the Green Book says to move vaccines to another fridge or a validated cool box for as short a time as possible. Scotland notes most incidents involve fridges over five years old and suggests planned replacement.

Status
Formal guidance
Applies to
GP practices, Community pharmacy
Last checked
18 October 2026
What temperature should my vaccine fridge be at?Guidance

Vaccines should be stored as their SPC says, which for almost all vaccines is +2°C to +8°C, protected from light and in their original packaging. The Green Book says good practice is to aim for +5°C, the middle of the range, and the 2026 UKHSA poster says 'Strive for 5°C'.

What's agreed, and what isn't

Some products differ: for example, Imvanex is delivered at -20°C and can be kept frozen or moved to +2°C to +8°C with a shorter expiry. Always check the SPC. Green Book chapter 3 is dated June 2013 inside the PDF (GOV.UK page shows first published 19 March 2013, never updated); some links and organisation names (HPA, DH protocol URL) are out of date.

Status
Formal guidance
Applies to
GP practices, Community pharmacy, Hospitals and wards, Care homes
Last checked
18 October 2026
How much vaccine stock should we hold?Interpretation

The Green Book says providers should hold no more than two to four weeks' supply and should order small quantities regularly. Vaccine Update issues from 2022 to 2025 told ImmForm customers to order no more than 2 weeks' stock of many products to limit losses from fridge failures. From 2026 the wording returned to 2 to 4 weeks of booked appointments.

What's agreed, and what isn't

UKHSA's own wording has moved between 2 weeks and 2 to 4 weeks depending on the product and the year. For seasonal flu vaccines and LAIV, UKHSA recommends no more than 2 weeks. Public Health Scotland says no more than two weeks in frontline clinical settings.

Source
Vaccine update: issue 374, August 2026 UKHSA, 28 August 2026
Status
Interpretation
Applies to
GP practices, Community pharmacy
Last checked
18 October 2026
Our treatment room reached 28 °C for three days during hot weather. Are the 'store below 25 °C' medicines still usable?Guidance

SPS says a single, isolated excursion of less than 5 °C above the labelled maximum storage temperature, lasting less than 7 days, is unlikely to have an adverse effect on medicines. A 28 °C peak over three days for products labelled 25 °C falls inside that. Some products allow up to 30 °C, and some have no stated storage conditions.

What's agreed, and what isn't

The rule covers a single, isolated event. It does not cover rooms that run hot every summer, which call for a documented risk assessment and possibly shortened expiry dates or cooling. SPS notes that Wholesale Dealer's Licence holders and others with regulatory requirements must still meet those requirements in full. The 2015 NHS Pharmaceutical QA Committee document quarantines ambient stock at a stricter point: more than 5 °C over the limit, or for more than a day.

Source
Managing temperature excursions NHS SPS, 9 July 2024
Status
Formal guidance
Applies to
Hospitals and wards, GP practices, Care homes, Community pharmacy
Last checked
18 October 2026
When does the HPRA expect a walk-in cold room or large fridge to be re-mapped?Guidance

IA-G0011 says large refrigerators and walk-in cold rooms should be mapped on installation in the empty and full states, with an ambient probe outside the unit. Re-mapping is expected after significant changes such as repair or replacement of the refrigeration unit, changes to internal layout, changes to set points, and changes to how duty/back-up condensers are run, including swapping which is main and which is back-up; if units are routinely rotated, both should be in the mapping study. Moving a small fridge may also require re-mapping.

What's agreed, and what isn't

These are specific triggers that go further in detail than the EU GDP text. The guide's wording varies in strength: re-mapping after a change to how duty/back-up condensers are run 'is required', while moving a fridge 'may' require it, and most other triggers use 'should'. None of it is a legal requirement. No fixed periodic re-mapping frequency is given.

Status
Formal guidance
Applies to
Wholesalers (WDA), Manufacturers
Last checked
18 October 2026
How often should we check the room temperature where medicines are stored?Guidance

SPS says min/max recorders are the minimum requirement in medicines storage locations. The 2015 NHS Pharmaceutical QA Committee guidance on clinical areas says all medicines storage areas should be routinely monitored. Min/max readings should be taken at least daily and the thermometer reset after each reading, with the thermometer placed in the worst-case location found by mapping or risk assessment.

What's agreed, and what isn't

Neither SPS page states a separate frequency for ambient areas. The daily figure comes from the 2015 NHS PQA document, which applies to NHS Trust wards and clinical areas. The SPS daily min/max wording sits under fridge-oriented alert guidance. Care homes and GP practices often adopt daily checks by analogy rather than because a national source requires them.

Status
Formal guidance
Applies to
Hospitals and wards, Care homes, GP practices, Community pharmacy
Last checked
18 October 2026
Do dental practices have to monitor the temperature of medicines storage?Interpretation

Yes. CQC dental mythbuster 35 says inspectors should see medicines stored securely, in an appropriate environment that follows the manufacturer's recommendations, with temperatures 'monitored regularly' and appropriate action taken if medicines are not stored correctly. Expiry dates of medicines and medical equipment should also be checked regularly. The example of good practice is staff regularly monitoring temperature to keep medicines within the manufacturer's limits.

What's agreed, and what isn't

The mythbuster does not define 'regularly' or say whether ambient storage and fridges are treated differently. CQC dental inspection reports often ask for daily fridge recording, but that is not written into the mythbuster.

Status
Interpretation
Applies to
Dental
Last checked
18 October 2026
What monitoring does a walk-in cold room need compared with a small fridge?Interpretation

Quoting the Green Guide, the MHRA blog says large commercial fridges and walk-in cold rooms should be monitored by an electronic temperature recording device that measures load temperature in one or more places, depending on size. Alarms should be fitted for power outages as well as temperature excursions. Condensate from chillers should not collect inside, and as much maintenance as possible should be done from outside the unit.

What's agreed, and what isn't

The number of sensors is not specified; it should follow mapping results. The 2016 MHRA deficiency data cited a walk-in fridge with dirt build-up around the fans and no cleaning schedule, so cleaning records are part of compliance.

Status
Interpretation
Applies to
Wholesalers (WDA)
Last checked
18 October 2026
If our home care agency looks after a client's medicines, are we responsible for fridge storage?Guidance

NICE NG67 says responsibility for storing medicines usually stays with the person and their family or carers. Where a social care provider has agreed to take it on, recommendation 1.10.4 asks for sound processes, including seeking health professional advice on safe storage if needed, identifying the need for fridge storage, assessing the need for secure storage and reviewing storage needs. Recommendation 1.10.1 asks for a risk assessment of transport arrangements where the provider is involved.

What's agreed, and what isn't

NG67 sets no temperature monitoring requirement for people's homes. The 2015 NHS Pharmaceutical QA Committee guidance also excludes patients' own homes from its scope.

Status
Formal guidance
Applies to
Care homes
Last checked
18 October 2026
What does NICE say care homes must have in place for medicines storage temperatures?Guidance

NICE SC1 recommendation 1.12.2 says a care home's process for storing medicines safely should include how and where medicines are stored, including fridge medicines and skin creams. It should also cover secure storage accessible only to authorised staff, and "the temperatures for storing medicines and how the storage conditions should be monitored". Recommendation 1.12.3 asks providers to assess each resident's storage needs.

What's agreed, and what isn't

NICE does not give temperature ranges, a check frequency, a fridge type or a retention period. It leaves these to the provider's process. Answers to 'do we need a dedicated medicines fridge?' or 'how often should we check the room?' therefore come from SPS, RPS, CQC or local ICB guidance, not NICE.

Source
Managing medicines in care homes (SC1) NICE, 14 March 2014
Status
Formal guidance
Applies to
Care homes
Last checked
18 October 2026

20-minute compliance check

How would you answer an inspector on temperature?

In 20 minutes we go through monitoring, alarms, mapping, calibration and excursions with you. You get the gaps in writing. No product tour.